Study on Cryocooler With an Active Gas Distribution System

王超,邱利民,董文庆,甘智华,张小斌
2011-01-01
Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics
Abstract:In order to overcome the disadvantages of traditional gas distribution system of G-M type pulse tube cryocooler, such as high irreversible losses during the intake and exhaust processes and power consumption, a novel active gas distribution system with middle stage reservoir is proposed. Theoretical analysis shows that active distribution system can reduce the power consumption of the compressor due to the reduction of irreversible losses during the intake and exhaust processes. The self-made pulse tube cooler with the active gas distribution system was tested. When the proportion of opening time of the middle stage reservoir is 30%, cryocooler reaches a lower temperature with minor decrease of cooling power. Besides, active gas distribution system increases the life time for valves.