Research on the Half-Wave Voltage Stability of Y Waveguide in FOG

Ying Liu,Yan Li,Zhongxiao Ji,Jintao Xu
DOI: https://doi.org/10.19650/j.cnki.cjsi.2010.02.035
2010-01-01
Abstract:Y waveguide is a key component of digital closed-loop fiber optic gyroscope, and the stability of its half-wave voltage directly affects the scale factor stability of FOG. Working temperature is the main factor that influences on the stability of Y waveguide half-wave voltage. Theoretical deduction of Y waveguide physical properties and experiment of half-wave voltage changing along with temperature indicate that the relationship between half-wave voltage and temperature is nearly linear. The non-linear errors are induced by Y waveguide electric field and mechanical stress. Through calibrating the Y waveguide half-wave voltage and making compensation, the optimal modulation state of FOG can be achieved and highly stable FOG scale factor can be obtained.
What problem does this paper attempt to address?