Experimental Study of Distance Between Heat Exchangers for Cooling Module Match

ZHANG Yi,YU Xiao-li,LU Guo-dong,XIA Li-feng,JIANG Ping-zao
DOI: https://doi.org/10.3969/j.issn.1000-0925.2006.05.011
2006-01-01
Abstract:To solve the match problem of multi-heat-exchangers module for vehicle cooling system,an extensive experimental investigation about the effectiveness of various distances between heat exchangers on module performance was carried out on the wind tunnel facilities.The first row of test module was charge air cooler(CAC) and hydraulic oil cooler(HOC),the second row was radiator,and the third is transmission oil cooler(TOC).The distance between each row of the first test module was 0 mm,the second was 100 mm,and the third was 200 mm.All the modules had the same heat exchangers.Different rates of heat transfer and pressure loss enhancement were obtained.The analysis of the test results show that increasing the distance can increase,but has different influnce on each heater of the module.So,the modulation of distance between different rows can make the heat exchanger module match design better.
What problem does this paper attempt to address?