An Experimental Study on Energy-saving Control of Multi-fan Cooling Module

Haimin Shi,Xiaoli Yu,Guodong Lu,Yuqi Huang,Zhentao Liu,Rui Huang
DOI: https://doi.org/10.19562/j.chinasae.qcgc.2017.01.017
2017-01-01
Abstract:To reduce the energy consumption of multi-fan cooling module, a testing platform for the per-formance of cooling module is set up, and an experimental study is conducted on modules consisting of different combinations of cooling units ( fan + radiator) . The results show that on the basis of comparing the performance of different cooling modules, the proposed segmented control scheme based on heat dissipation demands can meet ener-gy-saving requirements in different working conditions. Then further modifications indicate that adding shutters in fan duct can enhance module cooling performance by 7. 27% to 17. 73% at low heat dissipation demand segment;and by adjusting the fan speed ratio between low and high temperature zones to 0. 9 , the cooling performance of module can be further improved by about 1. 02% ~2. 13%.
What problem does this paper attempt to address?