Shroud depth structure of multi-fans cooling package

Hai-min SHI,Xiao-li YU,Yu-qi HUANG,Zhen-tao LIU,Si-wen LI,Guo-dong LU
DOI: https://doi.org/10.3785/j.issn.1008-973X.2017.09.019
2017-01-01
Abstract:The electrical fan module was established and numerically simulated by multiple reference frame method in order to study the performance of multi-fans cooling package (MFCP) influenced by shroud structural parameters.The radiator was simplified as porous medium,and the heat transfer characters was calculated by heat exchanger model.Then,the MFCP model was established.A test bench was set up to validate the simulation.According to the simulation,if the shroud was deeper,the aerodynamic and heat transfer performance of module would be developed,but the development would be minimized gradually.A parameter named most optimized shroud depth (MOSD) was defined according to the size and cost to evaluate the effect.To find out the MOSD further,it was found that there was little influence induced by the numbers of the fans,thus the study could be focused on the single fan module.The larger the area ratio is,the larger the MOSD is.The ratio of length and height do not influence the MOSD until it increases to a quite large value,which is 2.62 in our study.The effect by the radiator resistance and fan speeds are barely noticed.