Experimental Study of Inlet-outlet-tube Position of Heat Exchanger Module for Loader

Yi Zhang,Xiaoli Yu,Guodong Lu,Lifeng Xia,Pingzao Jiang
DOI: https://doi.org/10.3969/j.issn.1000-1298.2007.01.010
2007-01-01
Abstract:To solve the match problem of multi-heat-exchangers module for vehicle cooling system, an extensive experimental investigation on the effects of inlet-outlet-tube location of heat exchanger module for a loader was carried out in Yinlun wind tunnel. Test results discussed are related to 2 inlet-outlet-tube location prototypes, having the same heat exchangers, which includes charge air cooler (CAC), hydraulic oil cooler (HOC), radiator, transmission oil cooler (TOC). In the A type, radiator is up-down stream, and the inlet tube of the other three coolers are in the same side, the outlets in the other side. In the B type, only the inlet and outlet tube of TOC exchanged based on the A type. The analysis shows that if the inlet location changed, the heat transfer will be increased by about 3% in the design air velocity, and pressure drop changed a little. So, the modulation of inlet-outlet-tube location of heat exchangers is a choice for heat exchanger module match design. And in-depth research of heat transfer and pressure loss of cooling module based on test bench is very important for cooling system performance evaluation and matching design at present.
What problem does this paper attempt to address?