Study on heat transfer and friction characteristics in fin-tube heat exchangers used for electrical machines cooling

CHEN Jian,WU Jie,HONG Rong-hua
DOI: https://doi.org/10.3969/j.issn.1004-3950.2012.02.002
2012-01-01
Energy Engineering
Abstract:The characteristics of fin-and-tube heat-exchanger with new perforated fin used for electrical machines cooling were discussed.Three fin-and-tube heat-exchangers with different fin structures,perforated fin with 2.1 mm fin spacing,plain fin with 2.1 mm fin spacing and plain fin with 2.3 mm fin spacing,were tested.The test results show that heat-exchanger with new perforated fin has the best heat transfer performance and the highest pressure drop among the three structures.Heat transfer was augmented by 38%~39% compared with the plain fin with fin spacing of 2.1 mm,while pressure drop increased by 41.9%~42.9%.The comprehensive performance comparison showed the new perforated fin was better than plain fin with 2.1mm fin spacing for the Reynolds number higher than 6700.The heat transfer and friction factor correlations for three different fin structures were obtained in a wide range of Reynolds number,which could make help for further research and engineering applications.