Wind Tunnel Test of Optimization and Matching on the Cooling Package Performance of a Wheel Loader

Guodong Lu,Yu Xiaoli,Zhang Yi,Xia Lifeng
DOI: https://doi.org/10.3969/j.issn.1000-1298.2006.03.005
2006-01-01
Abstract:In a wheel loader, the charge air cooler(CAC), the hydraulic oil cooler(HOC), the radiator and the torque converter oil cooler(TCOC) are assembled together to form a cooling package, which is separated into 3 rows and arranged in the back end of the loader. With the increase of spacing between rows from 10 mm to 200 mm, when the cooling air speed is between 1.8~ 7.5 m/s, the heat exchange capability of the package rises by 5.1%~8.3% and the pressure drop reduces by 11.2%~20.5%. With the oil flow direction of the TCOC changed, when the cooling air speed is between 1.8~6.5 m/s, the heat exchange ability of the whole cooling package rises by 0.1%~6.2%. Enlarge the row spacing to a reasonable extent, can improve the performance of the cooling package and help to save the energy.