Abstract:To study the spacing effect on the cooling package performance,a rear mounted wheel loader's cooling package was tested on a wind tunnel test rig. The package is composed of charge air cooler(CAC),hydraulic oil cooler(HOC), radiator and torque converter oil cooler(TCOC),and is arranged into three rows.Different spacing values were selected in the test.Results showed that the spacing between the package components has close relationship with the package performance.Compared with the spacing of 10 mm,when the cooling air speed is between 1.8 ~10.0 m·s-1,the heat exchange capability of the package rises by 3.1%~7.4% and the pressure drop decreases by 1.8%~7.4% at 100 mm,while the heat exchange capability rises by 5.1%~10.9% and the pressure drop decreases by 8.1%~20.5% at 200 mm.Enlarging the spacing to a reasonable extent can benefit both the package performance and energy saving.