State analysis on reactor furnace pipe used over a design cycle

Ma Lifeng,Ding XiaoFei,Zhang Jun,Maokai Tian,GongLi Jing
DOI: https://doi.org/10.4028/www.scientific.net/AMR.535-537.529
2012-01-01
Abstract:Reformer furnace is the typical high-temperature equipment in petrochemical installations, but furnace pipe is the heart. The creep, thermal fatigue, thermal oxidation, carburization, corrosion and other phenomena may occur in harsh high temperature environments during service of furnace pipe. These factors make the properties degrade and life time short during all times of service. It will have significant economic losses if the rupture facture accident occurs suddenly. Comprehensive state analysis and life evaluation of reformer pipe run over service period to understand microstructure and property of furnace pipe by a range of material analysis methods, so that this will have important reference value for designer, manufacturer and user.
What problem does this paper attempt to address?