Influence of Contaminant with Sugar on Outer Insulation Performances of Insulator in Substation

梅红伟,毛颖科,王黎明,关志成
2012-01-01
Abstract:In order to find the reasons of strong discharge activity under low relative humidity of 500 kV substation insulators in China and to propose the appropriate solutions for avoiding this discharge activity,firstly,we investigated the pollution sources around the substation,analyzed the pollution layer condition of discharged substation insulators by field tests,and found a lot of sugar in the contaminant on the insulators' surface,thus,an inference that sugar as contaminant created the strong discharge of substation insulators was drawn.Then,we studied the influences of sugar as contaminant on outer insulation characteristics of glass insulator and room temperature vulcanization(RTV) coating insulator in detail.The surface conditions,the surface conductivities,the initial discharge voltages,and the flashover voltages of glass insulator and of RTV coating insulator were compared under the contamination with and without sugar.Also the hydrophobicity transference of RTV coating insulator were compared under the contamination in the presence and absence of sugar.Some important conclusions about contaminant with sugar were drawn.Finally,the specific solutions to inhibit the discharge activity of substation insulators under low relative humidity were given and the results after using these solutions were investigated.
What problem does this paper attempt to address?