Comparison of Axial Magnetic Field Characteristics of 5 Axial Magnetic Field Vacuum Interrupter Contacts

WANG Zhong-yi,LIU Zhi-yuan,ZHANG Xuan,WANG Ji-mei
DOI: https://doi.org/10.3969/j.issn.1003-3076.2006.01.006
2006-01-01
Abstract:Characteristics of axial magnetic field(AMF) of 5 kinds of vacuum interrupter contacts were studied with 3D finite element method,which included characteristics of AMF,eddy current in contact plates and phase shift time.The 5 AMF vacuum interrupter contacts include coil type,cup type,bipolar type,quadrapolar type and two coils type.The results showed that(1) from strong AMF to weak one generated by current,axial magnetic flux density at current peak followed with the order of coil type,bipolar type,two coils type,cup type and quadrapolar type;(2) from weak AMF to strong one at current zero,the order was quadrapolar type,bipolar type,cup type,two coils type and coil type;(3) from short phase shift time to long one at strong AMF,the order was bipolar type,quadrapolar type,coil type,two coils type and cup type.
What problem does this paper attempt to address?