Experimental Investigation of Vacuum Arc under Different Axial Magnetic Field Contacts for 40.5 Kv Vacuum Interrupters

Hongda Wang,Lijun Wang,Hongjian Wang,Qiang Ma,Cong Wang
DOI: https://doi.org/10.23919/isdeiv55268.2023.10199772
2023-01-01
Abstract:Axial magnetic field (AMF) can prevent the contraction of the vacuum arc, so it improves the breaking capacity of vacuum circuit breakers. The purpose of this paper is to study the vacuum arc characteristics under different AMF by experiments. Cup-shaped AMF contact, 2/3 coil-type contact, and 1/2 coil-type contact with a diameter of 120mm are used. The gap distance is fixed at 20 mm. The peak current ranges from 15 kA to 35 kA. The experimental results show that at the gap distance of 20mm, all three AMF contacts can keep the arc diffuse, although the arc appearance is slightly different. After the arc is ignited, the is a noisy period of arc voltage corresponding to the arc instability. The contraction on cup-shaped contact weakens with the increase of current level, while the contraction on 1/2 coil-type contact rises with the current level and the current level has a weak influence on the contraction. There is a re-ignition of arc on 1/2 coil-type contact at 35 kA and no reignition of arc on 2/3 coil-type contact and cup-shaped AMF contact. 2/3 coil-type contact and cup-shaped AMF contact can provide a greater breaking capacity.
What problem does this paper attempt to address?