Application and Key Technical Study of Composite Insulators

Guan Zhi-Cheng,Peng Gong-Mao,Wang Li-Ming,Jia Zhi-Dong,Zhang Ruo-Bing
DOI: https://doi.org/10.13336/j.1003-6520.hve.2011.03.031
2011-01-01
Abstract:It is about 20 years for composite insulators application of large scale in electric system in China.Because of its excellent antifilthy spark overability,composite insulators which were the inevitable choice to solve external insulation problem of UHVDC transmission project were used more and more in the transmission lines.The paper firstly introduces the manufacture,development and application of composite insulators in China,then analyzes and discusses the key technical study of the insulator,such as the environment and theory of break and brittle failure happened,test method of artificial pollution that about how to choose inert material,ambient temperature and transfer time,shed parameters of overhang and distance influenced the DC flashover voltage of insulator,infra-red and ultraviolet technique for on-line monitoring etc.The test results showed that inert material,ambient temperature and transfer time have a significant influence on the result;appropriate shed distance and overhang can greatly increased the DC flashover voltage of insulators;infra-red and ultraviolet technique have a remarkable effectiveness on on-line monitoring for composite insulator.
What problem does this paper attempt to address?