Study on the effect of three key geometric parameters of chevron corrugated brazed plate heat exchanger on the heat transfer performance

Qiao Xiaogang,Li Peng,Cui Liqi,Han Xiaohong,Chen Guangming
DOI: https://doi.org/10.3969/j.issn.1009-8402.2011.04.028
2011-01-01
Abstract:Based on the CFD Fluent software,builds a chevron corrugated plate heat exchanger model,and systematically analyzes the influence of three important parameters of geometry-corrugated angle,corrugated depth,corrugated spacing on the internal temperature field,pressure field,flow field,average Nusselt number and flow resistance on the water-water plate heat exchanger.The results show that the contact points are the best places for heat transfer between two heat exchanger plates and the disturbance of contact points make the strongest turbulences around the contact points,which is the main reason that the fluid turbulence occurs at lower Renault number for the plate heat exchanger and the heat transfer is enhanced.On the other hand,a greater pressure loss occurs after the fluid passes by the contact point,which is the main part of total pressure loss in the plate heat exchanger.Among the three geometric parameters,corrugated angle is the most important one and the best corrugated angle is about 60° with a good heat transfer effect and a moderate flow resistance.The average Nusselt number increases as the corrugated depth increases which enhances the heat transfer with a decreased pressure loss but is apt to scale,thus a corrugated depth of 4~5 mm is appropriate.It is also found that a ratio of the corrugated spacing to the corrugated depth of 3~4 is appropriate at the specified boundary condition.
What problem does this paper attempt to address?