Determination of PEG-Uricase Concentration in Plasma by RP-HPLC

范开,马雪丰,谢敏,胡春兰,谭克海
DOI: https://doi.org/10.3969/j.issn.1674-8425-b.2010.05.005
2010-01-01
Abstract:A rapid,stable and highly sensitive method for the determination of PEG-uricase concentration in plasma by RP-HPLC was established.The plasma samples reacted with uric acid for 5min,then the reaction was terminated by adding perchloric acid and high-speed centrifugate.The supernatant 20 μL injection was analyzed.The analysis was determined by RP-HPLC using C18 column(4.6×250 mm,5 μm) with a mobile phase consisting of phosphoric acid-methanol-water(3:10:487,v/v).The flow rate was 1.0 mL/min and the wavelength was detected at 293nm.The concentration of PEG-uricase in plasma was calculated indirectly by lowering the value of versus uric acid digest.The calibration curve of PEG-uricase concentration displayed highly relative linearity over the range of 31.25ng/mL-20ug/mL.The intra-day and inter-day RSD were not more than 10%.The average recovery was 88%-105%.
What problem does this paper attempt to address?