HPLC Determination of Pseudo-ephedrine Hydrochloride Concentration in Human Plasma

Wang Yu,Fang Yun,Ge Weihong,Tan Hengshan
DOI: https://doi.org/10.3969/j.issn.1002-7777.2007.02.022
2007-01-01
Abstract:A HPLC method to determine Pseudo-ephedrine hydrochloride(PSE)in human plasma was established.The human plasma was extracted with ether twice,and then extracted with 0.1M solution of sulfuric acid.Ranolazine was used as the internal standard.The sample was separated and determined with a Agilent Zorbax SB-C_(18) column with acetonitrile and a buffer solution(30mmol·L~(-1)SDS,30mmol·L~(-1) sodium dihydrogen phosphate,0.3%triethylamine)(50∶50) as the mobile phase at the flow rate of 1mL·min~(-1).The detection wavelength was at 210nm.A good linearity over the range of 19.0625~1220ng·mL~(-1) was achieved.All the RSD of intra-day and inter-day were less than 9.74%,and the recovery was more than 93.58%.This method is simple, sensitivity,accurate,and high precision,and could be used for the studies of PSE pharmacokinetics in human.