Determination of Cefpodoxime in Human Plasma by RP-HPLC with UV Detection

袁虹,孙凌,周权,阮邹荣
DOI: https://doi.org/10.3969/j.issn.1007-7693.2004.01.023
2004-01-01
Abstract:OBJECTIVE To develop a simple, sensitive and rapid RP-HPLC method for the determination of cefpodoxime in human plasma. METHOD The plasma samples were extracted with 1.25 mol×L -1 perchloric acid. The analysis involved a 150mm×4.6mm ID column packed with C 18( 5μm ). The mobile phase consisted of 1.50 mmol·L -1 perchloride acid solution-acetonitrile( 85∶15 ) with a flow rate of 1.20 mL·min -1. The UV detector were set at 254nm.RESULTS A good linearity was obtained in the rang of 0.10 ~ 6.00 mg·L -1( r=0.9999 ). The recovery was between 98.0% ~ 110.0%. The relative standard deviation of within-day and between-day were less than 13% ( n=6 ). The minimal detectable concentration in plasma was 0.10 mg·L -1. CONCLUSION The established method is sensitive, accurate and simple for the determination of cefpodoxime levels in human plasma. It is suitable for the pharmacokinetics and bioavailability study of cefpodoxime proxetil.