Determination of phenazopyridine hydrochloride in human plasma by LC-MS/MS

Tian-yun LI,Min-ji WEI
DOI: https://doi.org/10.3969/j.issn.1001-6821.2012.11.018
2012-01-01
Abstract:Objective To establish a new LC–MS/MS method for the determination of phenazopyridine hydrochloride in human plasma.Methods The analysis column was conducted with Capcell PAK C18.methanol-ammonium acetate(5∶15) was served as mobile phase.The flow rate was 0.15 mL·min-1.Detection was performed on a tandem mass spectrometry with electrospray ionization source.Multiple reactions monitoring mode was used to quantify phenazopyridine hydrochloride.Results The linear calibration curves were obtained in the range of 0.2-50.0 ng·mL-1for phenazopyridine hydrochloride.The extraction recovery for phenazopyridine hydrochloride were≥60.2%.The intra and inter day precision were≤11.5%.Conclusion The method is accurate,sensitive,and convenient,suitable for therapeutic drug monitoring and pharmacokinetic study of phenazopyridine hydrochloride.
What problem does this paper attempt to address?