RP-HPLC Determination of Chloroprocaine Concentration in Plasma

GU Jian,GAO Xu-mei,ZHANG Hai-ying,LI Yu-zhen
2005-01-01
Abstract:Objective: To establish an analytical method of the drug concentration in human plasma. Method: The RP-HPLC method was used. The plasma samples were subsequently extracted with ether after basification. The separation was carried out using Waters spherisorb ODS2(4.6mm×250 mm,5μm) column with mobile phase of 0.01mol·L~(-1) phosphate buffer (pH 3.0)-acetonitrile(30: 70). The internal standard was lidocaine. The flow rate was 1.2 mL·min~(-1). The detection wavelength for chloroprocaine and lidocaine were 300 and 210 nm, respectively. Results: The linear range for chloroprocaine was 0.01-25.0μg·mL~(-1). The correlation coefficient was 0.9998. The relative recoveries were 96.86% ,99.95% and 96.81% ,and RSD for intra-day and inter-day were both less than 8.3%. Conclusion: The method is accurate, simple and sensitive, and suitable for the study on pharmacokinetic of chloroprocaine in body.