RP-HPLC Method for Determination of Propofol in Human Serum

黄卓,王旗,王京宇,李群,吴新民,蒋建渝
DOI: https://doi.org/10.3969/j.issn.1001-6821.2003.04.013
2003-01-01
Abstract:OBJECTIVE: To develop a RP HPLC method for determining serum concentration of propofol. METHODS: The propofol was separated on a Diamonsil C_(18) column, the mobile phase was a mixture of acetonitrile and water (70:30, containing 0.10% trifluoroacetic acid). The excitation and emission wavelength were 276nm and 310nm, respectively. Sample preparation was simply a deproteinsation process with saturated ammonium sulphate. The propofol was extracted by the acetonitrile, the solvent of internal standard (thymol). RESULTS: A good linear relationship was obtained between 0.25 - 10 mg · L~(-1) (γ=0.9996). The detection limit was 25 Mg·L~(-1) with an injection volume of 20 μ L. The RSD of within-day and between-day were less than 2.5%, the average recovery was 91.2% - 100.9%. CONCLUSION: The proposed method is sensitive, reliable and can be used for pharmacokinetic studies of propofol and monitoring propofol in serum.
What problem does this paper attempt to address?