HPLC-APCI-MS Determination of Finasteride in Human Plasma

XUE Hong-yuan,LIU Jian-fang,HU Yu-qin,YU Yang,LIU Hui-chen
2005-01-01
Abstract:Objective: To establish a method for the determination of finasteride in human plasma using HPLCAPCI-MS. Methods: The plasma was alkalized with 1mol?L~(-1) sodium hydroxide and extracted with ether. The HPLC separation of finasteride was performed on a Diamonsil C_(18) analytical column with methanol-water(75: 25, consisting of formic acid 1% and ammonium formate 2mmol?L~(-1) as the mobile phase,a flow rate of 1. 0mL?min~(-1), injection volumn 10μL. A Agilent quadruple MSD equipped with an atmospheric pressure chemical ionization(APCI) source was used as detector and was operated in positive ion mode. Selected ion monitoring(SIM) was performed and the m/z of ions selected for quantitation were 373. 5(finasteride) and 285. 2(internal standard, diazepam). The nebulizer(N_2) pressure was at 124kPa. The drying gas(N_2) flow and its temperature were set at 3. 0L?min~(-1) and 250℃. Capillary voltage and fragmentor voltage were set at 4kV and 150V, respectively. Results: Chromatograms showed no endogenous interfering peaks with the respective blank human plasma samples. Each analysis was completed within 6. 5min. The linear range of finasteride in plasma was 1-128ng?mL~(-1). The method recoveries were 98. 5%-101. 7%. The intra-day and inter-day RSDs were less than 3. 3% and 7. 6%,respectively. Conclusions: The method was proved to be convenient, specific, accurate and sensitive enough to be applied to the pharmacokinetic studies of finasteride in human plasma.
What problem does this paper attempt to address?