Simultaneous determination of atorvastatin and its active metabolites in human plasma by LC-MS/MS

Han-jing CHEN,Hong-rong XU,Fei YUAN,Wei-li CHEN,Xue-ning LI
DOI: https://doi.org/10.13699/j.cnki.1001-6821.2017.06.017
2017-01-01
Abstract:Objective To develop an LC-MS/MS method for simultaneous determine the concentration of atorvastatin (AT) and its two active metabolites,ortho-hydmxyatorvastatin (o-AT) andpara-hydroxyatorvastatin (p-AT) in human plasma.Methods Deuterium-labeled compounds,o-AT-d5 and p-AT-d5were used as the internal standards.The analytes were extracted from human plasma through liquid liquid extraction method by using tert-butyl ether,after adding 5% formic acid.The chromatographic separation was achieved on a CAPCELL PAK C18(2.0 mm× 100 mm,TYPE∶MG Ⅱ,5 μm) column with the mobile phase,consisted of a mixture of acetonitrile-5 mmol · L-1 ammonium acetate buffer-formic acid (46∶ 54∶ 0.143,v/v/v),in isocratic mode at a flow rate of 0.40 mL · min-1.Data acquisition was carried out in multiple reaction monitoring (MRM) mode.Analytes were detected on a tandem mass spectrometer,equipped with an electrospray ionization source that was operated in the positive mode,using the transitions of m/z 559.3→m/z 440.2 for atorvastatin,and m/z 575.3→m/z 440.2 for both ortho-and para-hydroxyatorvastatin.The selectivity,standard curve,precision and accuracy,extraction recoveries,matrix effect,carry over and stability were investigated.Results The linear range of atorvastatin was 0.05-100 ng · mL-1.The linear regression equation was y =4.35 × 10-2x + 3.43 × 10-4 (r =0.999 3) with the lower limit of quantitation (LLOQ) of 0.05 ng · mL-1.The linear range of ortho-atorvastatin was 0.05-50 ng· mL-1.The linear regression equation was y =1.03 × 10-1x + 6.93 × 10-4 (r =0.998 7) with the lower limit of quantitation (LLOQ) of 0.05 ng · mL-1.The linear range of para-atorvastatin was 0.05-5.0 ng · mL-1.The linear regression equation was y =5.35 × 10-1 x-2.26 × 10-3 (r =0.998 4) with the lower limit of quantitation (LLOQ) of 0.05 ng · mL-1.The intra-day and inter-day relative standard deviations (RSD) of LLOQ,low,medium1,medium2 and high concentrations of atorvastatin were both less than 15%.The extraction recoveries were 61.64%-90.29%.The matrix effects were 88.74%-105.62%.Conclusion The established method is rapid,sensitive,accurate,specific and reliable,and suitablefor simultaneous determination of atorvastatin and its active metabolites (ortho-atorvastatin and para-atorvastatin) in human plasma,which meets the needs of clinical therapeutic drug monitoring and pharmacokinetics research.
What problem does this paper attempt to address?