HPLC method for determination of methotrexate in human plasma*

HUO Jing,YUAN Sheng-hua,FANG Yun,GE Wei-hong
DOI: https://doi.org/10.3969/j.issn.1673-7806.2007.05.016
2007-01-01
Abstract:Objective:To establish a RP-HPLC method for the determination of methotrexate in human plasma.Methods: The LC-10AD HPLC apparatus and Lichrosphere C18 column(5 μm,4.6 mm×250 mm) were used with a mobile phase consists of 0.025 mol·L-1 NaH2PO4(pH5.5)-methanol(72∶28).The detection wavelength was 313 nm.The flow rate was 1.0 mL·min-1.Internal standard was ferulaic acid.Results: The linear range of the calibration curve was 0.05~5.00 μg·mL-1.Linear equation: Y=3.094 2c+0.006 8(r=0.999 3).The inter-and intra-day precision were below 7% and below 10% respectively.The limit of detection was 20 ng·mL-1.Conclusion: The mothod is simple,which can be used in determination of methotrexate in human plasma and pharmacokinetic studies.