Determination of Uric Acid in Human Serum Using a Revered-Phase High Perfermance Liquid Chromatography

沈巍,徐国宾,张曼
DOI: https://doi.org/10.3969/j.issn.1673-8640.2009.08.004
IF: 1.865
2009-01-01
Laboratory Medicine
Abstract:Objective To evaluate the revered-phase high performance liquid chromatography(HPLC) with 5-fluorouracil(5-FU) as an internal standard for serum uric acid(UA) determination,and to recommend this method as a candidate reference method.To evaluate biases of results of serum uric acid determination by uricase-peroxidase-trinder methods according the revered-phase HPLC result.Methods The methodology of the revered-phase HPLC was evaluated.The result accuracy of serum UA by the revered-phase HPLC was verified according to determine a certified reference material(SRM) and the Survey RELA KS(1/06) serum sample of RELA 2006 4th IFCC Ring Trial for Reference Laboratories.The revered-phase HPLC as a comparison method and the uricase methods with closed-system including Beckman,Roche,Dade,Vitros and opened-system including Beckman,Roche as a test methods.61 samples of serum UA were determined by two methods respectively,which formed six comparison groups.The scatter figures,bias figures,linear equations and correlation coefficients of comparison data in each group were made and the biases of measurement results were evaluated.Results The linear range of HPLC was up to 1 190 μmol/L.The intraassay coefficient of variation(CV) and interassay CV of HPLC were 2.1% and 3.9%,respectively.The Absolute recoveries were 96.2%-101.0% and the average relative recoveries were 95.1%-99.4%.The average relative bias was-8.29% for the determination of UA level in SRM by HPLC.Compared with result of isotope dilution mass spectrometry,the relative biases were-3.45% to-1.26% when determined the samples of IFCC by HPLC.There was good correlation between the comparison method(HPLC) and the test method(closed-system including Beckman,Roche,Dade,Vitros and opened-system including Beckman)(R2=0.996 9,0.997 2,0.995 2,0.996 7,0.997 3,0.994 7).When the levels of UA were 120,470,630 μmol/L,the predicted relative bias ranges were-14.6%-4.3%,-0.4%-8.0%,0.8%-8.8%,respectively.There was good consistency between Beckman closed-system and revered-phase HPLC.The results of Roche closed-system in the low value range were lower.The Dade and Vitros closed-system in the high value range were higher.The results of closed-system were slightly better than opened-system.Conclusions The revered-phase HPLC with 5-FU as an internal standard is recommended as a candidate reference method for serum UA determination.There were some biases among the results of uricase method in different systems.
What problem does this paper attempt to address?