Determination of Catecholamines in Urine by High Performance Liquid Chromatography Coupled with Fluorescence Detector

Wang Lulu,Ge Weihong,Fang Yun
DOI: https://doi.org/10.3969/j.issn.1008-049X.2009.09.015
2009-01-01
Abstract:Objective:To establish a simple and accuracy method for determine the concentration of catecholamines in urine by HPLC-FLD.Method:Samples were cleaned-up by alumina solid-phase extraction cartridge homemade,and DHBA was used as internal standard.The solid phase was Agilent Zorbax SB-C_(18)(250 mm×4.6mm,5μm),and the mobile phase was a mixture of methanol- 0.02mol·L~(-1)Kalium Hydrogen Phospharate(contain 0.2 mmol·L~(-1)EDTA-2Na)with a flow rate at 0.9 ml·min~(-1)and the temperature was 23℃.Result:The linear concentration range for norepinephrine was 3.6-115.2 ng·ml~(-1),for epinephrine was 14.85-475.2 ng·ml~(-1)and for dopamine was 28.65-916.8 ng·ml~(-1).The average recovery was about 80%with both the intra-day RSD and the interday RSD at less than 7%.And all of catecholamines were very stable when protected from light.Conclusion:The method is high sensibility and accuracy,which can be used for concentration detecting of catecholamines and correlative diseases study at clinic.
What problem does this paper attempt to address?