Determination of leu-enkephalin (L-EK) drugs by a novel high performance liquid chromatographic method with fluorimetric detection (HPLC-FLU)

XIA Yu-qin,Ye Lu,LIU Jia-chi,LIANG Jian-ying
DOI: https://doi.org/10.3969/j.issn.1672-8467.2012.03.016
2012-01-01
Abstract:Objective: To establish a novel high performance liquid chromatographic method with fluorimetric detector (HPLC-FLU), by using pre-column redox derivatization for the determination of leu-enkephalin (L-EK) drugs. Methods: L-EK was mixed with 0.012 mol/L sodium periodate, 0.01 mol/L catecholamine and 0.3 mol/L boric acid (2:2:1:1, V/V). The mixture was heated at 120°C for 10 minutes. The chromatographic separation was performed on an ODS column with 0.25 mol/L borate buffer (pH 7.6)-methanol as mobile phases with gradient elution. The derivatized compounds were detected with fluorimetric detector. L-EK was detected by this method in vitro and in human plasma, compared with HPLC-UV and HPLC-FLU with pre-column O-phthalaldehyde (OPA) derivatization. Results: The linear range of HPLC-FLU with pre-column redox derivatization was 0.5-50.0 mg/L (r=0.999 8) in human plasma and the limit of detection was 0.1 mg/L. This method was better than the other two not being disturbed by endogenous substances. Conclusions: HPLC-FLU with pre-column redox derivatization has advantages in detecting L-EK in human plasma.
What problem does this paper attempt to address?