Rapid and sensitive determination of four bisphosphonates in rat plasma after MTBSTFA derivatization using liquid chromatography-mass spectrometry
Hui-Xia Zhang,Yan Li,Zheng Li,Christopher Wai Kei Lam,Hong-Wei Chen,Wen-Di Luo,Cai-Yun Wang,Zhi-Hong Jiang,Zhi-Yun Du,Wei Zhang
DOI: https://doi.org/10.1016/j.jpba.2020.113579
IF: 3.571
2020-10-01
Journal of Pharmaceutical and Biomedical Analysis
Abstract:<p>Bisphosphonates (BPs) have broad medical applications against osteoporosis, bone metastasis and Paget's disease. The BP-related jaw osteonecrosis limits their use extensively and has a causal relationship with the process of drug disposition, such as deposition on bone and slow elimination rate. Thus it is imperative to accurately determine BP levels in either clinical or pharmacological/toxicological studies. The ability of trimethylsilyl diazomethane (TMSD) to alkylate the hydroxyls in phosphoric groups is an advantage in terms of decreasing polarity and enhancing mass response of BPs. There are, however, practical limitations to the cumbersome sample preparation procedure, the prolonged reaction time, the by-products and the obstacle to ionization. To overcome these disadvantages, a simplified and rapid precolumn derivatization method with N-(tert-Butyldimethylsilyl)-N-methyl-trifluoroacetamide (MTBSTFA) to quantify etidronate, clodronate, alendronate and zoledronate BPs in rat plasma was established in this work. The derivatization reaction was conducted within 2 min at room temperature, and the unitary di-tert-butyldimethylsilyl (di-tBDMS) derivative was obtained for each BP. Derivatives were separated on a XTerra® MS C<sub>8</sub> column (2.1 × 50 mm, 3.5 μm) with the mobile phase of 5 mM ammonium acetate buffer (pH 8.5) and acetonitrile, then detected using electrospray ionization tandem mass spectrometry in negative mode. An easy extraction process instead of the time-consuming solid-phase extraction (SPE) was employed for plasma treatment. The proposed method showed good linearity for BPs over the range of 2-500 ng/mL in 20 μL plasma and high sensitivity owing to the larger molecular ions, higher ionization capacity and more stable fragments of di-tBDMS derivatives. The intra- and inter-batch precision was <13.1%, and the accuracy ranged within ±10%. The extraction recovery varied from 75.4 to 88.0%. The optimized method was successfully applied to characterize the pharmacokinetic profile of zoledronate in rats. Moreover, it is a promising approach for the determination of other phosphoric acid-containing metabolites.</p>
pharmacology & pharmacy,chemistry, analytical