Abstract:Severe leakage occurs in the collection pipeline at the outlet of air cooler in the distillation column, which leads to an unplanned shutdown. In order to reveal the root cause of the leakage, the corrosion process under oil–water two-phase flow in the horizontal-vertical pipeline was investigated by macroscopic observation, thickness measurement, microscopic analysis, and computational fluid dynamic (CFD) simulation. The results show that flow-accelerated corrosion (FAC) is the main reason for the leakage in the pipeline. The water volume fraction and wall shear stress are the crucial parameters in the corrosion process. The water volume fraction determines whether corrosion occurs by influencing the process of water wetting the wall of the pipeline. Fluid flow in the corrosion acceleration process is represented by the wall shear stress. The region of high water volume fraction and high wall shear stress is basically the same as the region of actual leakage. When the water cut inside the pipeline decreases by half, the corrosion risk of the pipeline is greatly reduced.