Failure Analysis of A Pipeline in Sour Gas Field

Tan Gu,Honggang Chang,Qiang Zhang,Nange Zhang,Zhide Liu,Hua Wu,Guiyang Wu,Mengwei Yang,Lin Mo,Jing Yan
DOI: https://doi.org/10.1142/9789814678971_0086
2015-01-01
Abstract:The main reasons for corrosion failure of pipeline in sour gas field have been proposed based on the analysis techniques of Optical Microscopy (OM), Scanning Electron Microscope (SEM), Energy Dispersive Spectrometer (EDS) and X-ray Diffraction (XRD). The results show that the leakage happened caused by pit corrosion in the test samples. Pit corrosion occurs under the condition of wet H2S corrosion, while fouling and Cl-do promotion. Test pipe material properties meet the conditions requirements of China. According to the condition of pipeline corrosion, it is suggested that the raw gas should process gas-water separation before transportation, and the filter unit should be added to reduce the sand and gravel content.
What problem does this paper attempt to address?