Abstract:The maximum thickness for ferritic steel specimens' residual stress measurements using neutron diffraction is known to be about 80 mm. This paper proposes a new neutron diffraction configuration of residual stress measurements for cases that are over 80 mm thick. The configuration utilizes a neutron beam with a wavelength of 1.55 Å diffracted from the (220) plane with a diffraction angle (2θ) of 99.4°. The reason for the deep penetration capability is attributed to the chosen wavelength having enough intensities due to the low cross-section near the Bragg edge and the reduced beam path length (~16 mm) reflected by the large diffraction angle. Neutron diffraction experiments with this configuration can decrease strain errors up to ±150 με, corresponding to a stress of about ±30 MPa.
materials science, multidisciplinary,metallurgy & metallurgical engineering