Effect of sub-cooling on fuel channel behaviour during LOCA for Indian PHWR

Madhuri Bhadauria,Ravi Kumar,Arup K. Das,Deb Mukhopadhyay,Prasanna Majumdar
DOI: https://doi.org/10.1016/j.nucengdes.2024.113029
IF: 1.7
2024-02-25
Nuclear Engineering and Design
Abstract:During LOCA with ECCS failure, the removal of decay heat from the channel to a moderator plays a significant role in determining the fuel bundle temperatures. An experimental investigation has been carried out to study the effect of change in moderator temperature (65 °C, 75 °C, and 85 °C) on the fuel channel at a steady state of 900 °C center pin temperature. The results show that at different moderator temperatures, there is insignificant variation in the temperature of PT, whereas for CT appreciable temperature gradient has been observed. The maximum heat transfer coefficient for CT was attained at 65 °C moderator temperature. Even with an increase in moderator temperature, channel integrity is maintained, and the moderator acts as an ultimate heat sink for all three moderator temperatures.
nuclear science & technology
What problem does this paper attempt to address?