Deterministic analysis of residual heat removal from activated EU DEMO WCLL BB segments during ex-vessel LOCA

Martin Draksler,Boštjan Končar,Christian Bachmann,Ivo Moscato,Sergio Ciattaglia,Alex Valentine
DOI: https://doi.org/10.1016/j.fusengdes.2024.114190
IF: 1.905
2024-01-27
Fusion Engineering and Design
Abstract:The residual heat removal from the activated EU DEMO WCLL breeding blankets (BB) in the event of impaired cooling due to an ex-vessel Loss of Coolant Accident (LOCA) is investigated. The postulated guillotine break of a large coolant pipe of the BB Primary Heat Transfer System (PHTS) outside the vacuum vessel (VV) leads to an immediate loss of cooling in one (out of two independent) BB cooling loops. Consequently, every second BB segment (in the toroidal direction) is assumed to be affected. To mitigate the consequences, the plasma ramp-down is initiated and the VV is filled with helium to enable the natural convection cooling of the passive BB segments by the circulating gas. A transient conjugate heat transfer analysis with the ANSYS Fluent code has been conducted to assess the thermal response of the affected BB segments and to quantify the effectiveness of the natural convection cooling in respect to thermal radiation and heat conduction through supports. The feasibility of the proposed helium cooling solution for the residual heat removal from the activated BB segments is investigated and a comparison with a conservative study where all BB segments are assumed to be affected by LOCA is discussed.
nuclear science & technology
What problem does this paper attempt to address?