Failure Analysis of Compressor IGV in 9F Gas Turbine Generator Unit

Gu, Shuchao,An, Dong,Qiu, Guoping,Wang, Ruixuan,Liu, Yuzhe
DOI: https://doi.org/10.1007/s11668-022-01440-7
2022-07-13
Journal of Failure Analysis and Prevention
Abstract:Several compressor inlet guide vanes (IGV) with cracks of 9F gas turbine generator unit have been found fractured during the inspection process. The purpose of this paper is to find out the failure cause of those fractured IGV in terms of visual inspection, metallographic examination, chemical component analysis, microscopic fracture analysis, hardness test and energy spectrum analysis and so on. Macro-observations showed that all the breaking points were located at the chamfering position of IGV root, where exits the stress concentration confirmed by the stress analysis. According to the results of energy spectrum analysis, the corrosive element such as chlorine and sulfur were enriched on the IGV surface, producing local pitting corrosion and formation of corrosion fatigue source. In addition, the coarse martensite structure and organizational segregation of individual IGV by means of metallographic examination resulted in the performance degradation including strength and corrosion resistance, which accelerated the formation and propagation of the stress corrosion fatigue crack.