Failure Analysis of Ruptured Bolts in Coal Gas Heater

朱岗,邱艳丽,杨振国
DOI: https://doi.org/10.15943/j.cnki.fdxb-jns.2008.03.011
2008-01-01
Abstract:The failure mechanisms and causes of the ruptured bolts of blind plate on a coal gas heater of 350 MW gas turbine generating unit were systematically studied. A series of macroscopic and microscopic analysis methods were used to characterize chemical composition, metallographic structure, macroscopic appearance, microscopic morphology and micro-area chemical composition of the bolts. The experimental results showed that the failure of the bolts were mainly caused by galvanic corrosion, crevice corrosion and followed stress corrosion cracking, which were resulted from inferior material, unqualified processing quality, and unsuitable fastening force and corrosive environment. The relevant mechanisms on crevice corrosion and stress corrosion cracking of the bolts were carefully discussed and countermeasures for preventing the bolts were also proposed.
What problem does this paper attempt to address?