Failure Analysis of a MW-Class Wind Turbine Blade Root Bolt

Zhunbei Zheng,Xiaochen Wang,Wenbin Guo,Zhanjun Yang,Xingxin Sun,Xiuguang Li
DOI: https://doi.org/10.1007/s11668-019-00683-1
2019-08-01
Journal of Failure Analysis and Prevention
Abstract:Failure analysis of a fractured high strength bolt used in a MW Class wind turbine blade connection system was conducted to clarify the failure cause and to determine the prevention method. Applying detailed mechanical characteristics and metallurgical investigations, the bolts failure cause can be attributed to bending fatigue. Evidenced by the nut polished markings, insufficient tightening was considered as the important reason for the bolt failure. The thread microstructure indicated that the fractured bolt thread was rolled rather than machined. However, rolling induced cracks locating on the thread crest and non-uniformly distributed decarburized layer on the bolt thread root existed. Thus, it can be concluded that the bolt failure was caused by the insufficient tightening and improper manufacturing procedure.