Failure Analysis and Countermeasure of Heat Exchangers in Nuclear Power Facility

YANG Zhen-guo
DOI: https://doi.org/10.3969/j.issn.0254-6051.2007.z1.006
2007-01-01
Abstract:By using about twenty macroscopic and microscopic analysis techniques and testing methods,failure analysis on a number of leakage cases of heat transfer titanium tubes,which occurred in some heat exchangers of nuclear power facility with type of CANDU-6 from abroad,was systematically carded out.Through observation and analysis on fractographs of the failure tubes,a new kind of failure mechanism by hydrogen-blistering existed in the tubes under circumstance of seawater was firstly found at home and abroad;other five kinds of failure mechanisms as well as their corresponding morphology distinctions were also revealed.It was definitely identified that the inappropriate ways adopted in design,manufacture and installation of the tubes,resulting in their premature failure, were primary causes and chocking of the tubes resulted from some foreign materials like oyster shell,sediment,and rubber-lined belt,etc.was the other important cause.A series of specific countermeasures,which have been demonstrated successfully after implementation,were thus put forward.Moreover,the achievements obtained can also provide instructive significance for ensuring effective protection and safety operation of heat exchangers running under circumstance of seawater in some industries such as nuclear power,electric power,petrochemical,chemical, metallurgy and so on.
What problem does this paper attempt to address?