Failure Analysis of O-ring Gaskets of the Electric Hydraulic System in the Nuclear Power Plant

Xiao-Lei Yang,Zhen-Guo Yang,Qun Ding
DOI: https://doi.org/10.1016/j.engfailanal.2017.04.021
IF: 4
2017-01-01
Engineering Failure Analysis
Abstract:In this paper, premature failure of the O-ring gaskets for the electric hydraulic system in a nuclear power plant in China was investigated. A series of macroscopic and microscopic analysis methods were conducted to identify the root causes of this unexpected failure, and the results showed that mismatch of the sizes between the O-ring gaskets and the groove of metal union was the primary reason, which gave rise to the permanent distortion and surface damage of the O-ring gaskets, and consequently leading to fracture under service conditions. Countermeasures were then proposed to prevent the recurrence of similar incidents, and were proved effective on site.
What problem does this paper attempt to address?