Abstract:The functionality of the main pump in a nuclear power plant is to circulate the primary coolant in the reactor coolant system. To maintain the normal operation of the main pump, several kinds of sealing components are used to avoid the leakage of the coolant. However in this paper, the primary coolant leakage of the main pump still occurred accidentally in a nuclear power plant in the coastal area of China. After disassembling, it turned out that the O-ring of the bearing cap on the radial thrust bearing room had prematurely failed. Therefore, a series of materials char-acterizations were conducted on the O-ring to find out the causes, including the macro/micro-scopic morphologies observation, matrix materials examination, and properties evaluation. The obtained results showed that the severe swelling caused by the exposure to the improper hydrocarbon organic media during service was the root cause of this premature failure, based on which relevant countermeasures and prevention methods were proposed to avoid the reoccurrence of similar cases.
What problem does this paper attempt to address?