Thermal Analysis on Bearing Body of Residual Heat Removal Pump in Nuclear Power Plant

TENG Guo-rong,LI Yan-jun,YAN Jian-hua,HUANG Dao-jian
DOI: https://doi.org/10.3969/j.issn.1005-0329.2011.12.008
2011-01-01
Abstract:Heat removal pump is important for nuclear power plant during its suspending period.And bearing body is the key components for the pumps to operate safely and stably.The heating status of bearing body were analyzed based on heat transfer theory.The results show that the heat quantity transferred from pump body to bearing body by the axis and the heat quantity generated from bearing high-speed rotating friction are both absorbed by bearing body,and the the temperature of bearing body is too high to run safely.So the recycled water should be use for cooling.The relations were analyzed between recycled water flow and its outlet temperature.
What problem does this paper attempt to address?