Dealing with problem of over-limit temperature of thrust bearing pad in scooptype water-turbine generator set at Yele Hydropower Plant

He Ding-quan
Abstract:That the temperature of thrust bearing pad exceeds the alarm temperature designed for unit No.1 at Yele Hydropower Plant impedes the normal operation of the unit.Shutdown analysis shows that nonuniform stress distribution in the bearing pad,the poor heat exchange,the inherent drawback of the cooling system,etc.are the main causes.Some measures are taken to deal with the above problems,including adding of 12 pores with the diameter of 40?mm on the bearing pad to make the oil stream flow more smoothly and rapidly and to increase the amount of heat exchange;canceling of casing tube in cooling apparatus to make the heat exchange between oil and water more sufficiently;adding of 6 coolers and a set of pipeline for water supply and discharge at the symmetrical side of the original pipes.Through the adoption of the measures and reformation of the device,the temperature of the bearing pad returns to its normal value,and the safe and stable operation of the unit is realized.
Engineering,Environmental Science
What problem does this paper attempt to address?