Beam Position and Phase Measurement System for the Proton Accelerator in ADS
Lei Zhao,Xingshun Gao,Xiaofang Hu,Shubin Liu,Qi An
DOI: https://doi.org/10.1109/tns.2013.2291779
IF: 1.703
2014-02-01
IEEE Transactions on Nuclear Science
Abstract:A prototype of a beam position and phase measurement system is designed for the proton accelerator in the China Accelerator Driven Sub-critical system (ADS). The signals from the Beam Position Monitor (BPM) detector are narrow pulses with a repetition frequency of 162.5 MHz and the input amplitude would vary for more than 40 dB. By applying the high-speed high-resolution analog-to-digital conversion technique, the input radio-frequency (RF) signals are directly under sampled to orthogonal streams by precisely adjusting the sampling clock frequency. Compared with the traditional method to obtain the in-phase and quadrature-phase (IQ) data, it simplifies both the analog and digital processing circuits. All signal processing algorithms are integrated within one field programmable gate array (FPGA) chip for a good system simplicity. Initial testing results indicate that this prototype achieves a phase resolution better than 0.03° and a position resolution better than $5~\mu\hbox{m}$ over the input amplitude range from $- {44}~\hbox{dBm}$ to $- {4}~\hbox{dBm}$, well beyond the requirement.
engineering, electrical & electronic,nuclear science & technology
What problem does this paper attempt to address?