On-line crosstalkmeasurement and compensation algorithm study of sxfel digital bpm system ∗

F. Z. Chen,Y. B. Leng,J. Chen,L. Y. Yu,L. W. Lai,R. X. Yuan,T. Wu
2018-01-01
Abstract:Shanghai soft X-ray Free Electron Laser (SXFEL) has acquired the custom designed Digital BPM processor used for signal processing of cavity BPMs and stripline BPMs. In order to realize monitor the beam position accurately, it has high demand for DBPM system performance. Considering the crosstalk may introduce distortion and influence beam position resolution, it is important to analyze and compensate the crosstalk to improve the resolution. We choose the CBPM signal to study the crosstalk for its narrowband and sensitive for phase position. The main experiment concept is successive accessing four channels to form a signal transfer matrix, which including amplitude frequency response and phase response information. And the compensation algorithm is acquire four channel readouts, then using the signal transfer matrix to reverse the true signal to ensure the accurate beam position measurement. This concept has already been tested at SXFEL and hopeful to compensate the crosstalk sufficiently. BACKGROUND SXFEL SXFEL is one of the high-gain FELs constructed in China. Key technologies have been tested through prototype developments. Based on the research and development prototype of hard X-ray FEL. The construction of the user facility in soft XFEL has already finished. The SXFEL facility consists of an electron injector with a thermionic cathode, main accelerate section including C-band high-gradient accelerators along with S-band accelerators, and in-vacuum undulators. Figure 1 is SXFEL undulator layout [1, 2]. SXFEL is designed to generate a coherent x-ray beam using a self-amplified spontaneous emission (SASE) process. ∗ Work supported by National Science Foundation of China (No.11375255) † chenfangzhou@sinap.ac.cn ‡ lengyongbin@sinap.ac.cn In order to meet the harsh demands, the beam diagnostic system achieving high precision resolution is one of the most important technical issues. Cavity BPM meets the hash demands for the precise measurement of the resolution of the SXFEL undulators system. Figure 2 is the picture of one Cavity BPM installed in the tunnel. Figure 2: Cavity BPM installation spot picture. Cavity BPM CBPM is a key beam instrumentation component for SXFEL beam diagnostics. As the requirement of undulator should reach sub-micron level position resolution. The high Q cavity BPM. As the key beam diagnostics tool, BPM systems are widely equipped in all kinds of accelerators. Cavity Beam Position Monitors are main beam diagnostic instruments in SXFEL. There are more than 20 CBPM conducted in SXFEL used for the measurement and adjustment of beam orbit. Moreover, the sum of four SBPM electrodes signal can also apply in relative beam charge measurement. RF cable extract beam signal from CBPM pickup, RF front-end module modulated signal to proper amplitude, then led the signal to digital BPM processor. Figure 1: Partial layout of SXFEL undulator. 7th International Beam Instrumentation Conference IBIC2018, Shanghai, China JACoW Publishing ISBN: 978-3-95450-201-1 doi:10.18429/JACoW-IBIC2018-MOPC17
What problem does this paper attempt to address?