Progress of Cavity Beam Position Monitor at SXFEL

Longwei Lai,Zhichu Chen,Yongbin Leng,Yingbing Yan,Luyang Yu,Renxian Yuan,Weimin Zhou
DOI: https://doi.org/10.18429/jacow-ibic2015-tupb036
2016-01-01
Abstract:Shanghai Soft X-ray FEL Test Facility (SXFEL) has started the infrastructure construction in 2015. All beam diagnostic systems are under processing and measurement, including C-band Low-Q cavity BPMs. This paper presents the progress of the cavity BPM system, including design and the measurements on a lab platform. Measurements shown that the cavity BPM frequency is 4.7GHz ± 8MHz, and the complete test platform verify that the cavity BPM system, which including signal processing electronics can work as expected. INTRODUCTION The SXFEL project at the Shanghai Synchrotron Radiation Facility (SSRF) campus serves as a test facility of China’s future hard X-ray FEL user facility, while it can be easily upgraded to a FEL user facility at“waterwindow” spectral region for scientific investigations with high brilliance X-ray pulses of ultra-fast and ultra-high resolution processes in material science and physical biosciences. The construction of the SXFEL has started since April 2015, and the first X-ray FEL light is planned to be delivered to the beam line in 2017. The SXFEL consists of following parts: 1. A photo-injector generating a bright electron beam and accelerating it to ~ 130 MeV. 2. The main linear accelerator, where the electron beam is longitudinally compressed and accelerated to ~ 840 MeV. 3. The FEL undulator complex where X-ray radiation is generated. 4. The photon beam transport & diagnostic line. To achieve the physical design of SXFEL, the diagnostic system need to achieve requirements listed in Table 1, and the dynamic is 0.1nC~0.5nC. CAVITY BPM SYSTEM The cavity BPMs have been chosen for the real time measurements of the electron beams positions along the undulator of the SXFEL. The layout is shown in Fig. 1. Figure 1: Layout of cavity BPM along undulator. Table 1: Beam Diagnostics System Specification Parameter Main technical specifications Position Stripline BPM, Resolution: 10μm@0.5nC Cavity BPM, Resolution: 1μm@0.5nC Size YAG/OTR, Resolution:30μm@1nC, Repeatablity:50μm Charge ICT, Resolution:1% Length CSR, Resolution:100fs Arrive time Phase cavity, Resolution:200 fs Cavity BPM Pickups The cavity BPM system consists of the cavity BPM probes, the RF front-end and data acquisition (DAQ) electronics is shown in Table 2. The working frequency of the position mode and the reference cavity of the CBPM are designed to be 4.7GHz preliminary to avoid the interference of the dark current caused by the frequency multiplication of the RF. The signals will be lead out through the 50Ω load and the system quality factor will be mainly determined by the external quality factor. Table 2: The Cavity BPM Design Parameter Parameter TM110 TM010 Frequency 4.7GHz 4.7GHz Q ~60 ~60 Ports number 4 2 Signal amplitude@50Ω 12mV/μm/nC (peak) 100V/nC (peak) CBPM responses with a series of simulated electron beams passing the CBPM at different positions have been modeled with MAFIA. The output signal and the corresponding spectrum at the electrode of the CBPM are shown here in Fig. 2. Stage-1 Stage-2 UN-POP UN-POP UN-POP UN-POP UN-POP UN-POP UNPRF
What problem does this paper attempt to address?