Study on a New Method of Determining Boiler Soot-blowing Steam Flow Rate

H Y Chen,Z H Xue,X X He,D S Pei,P F Zhangand,J F Sun
DOI: https://doi.org/10.1088/1755-1315/701/1/012024
2021-03-01
IOP Conference Series: Earth and Environmental Science
Abstract:Abstract In this paper, a new method of determining boiler soot-blowing steam flow rate was proposed. By this method, three tests of unaccounted-for leakage rate of the unit thermal system should be conducted without soot blowing, and the unaccounted-for leakage ratio difference between arbitrary two tests should be within 0.10%. The average value of three unaccounted-for leakage flow rate test results was used as the final result of unit unaccounted-for leakage flow to determine the flow rate of soot-blowing steam. During the test period of power output and heat rate, the calculation of soot blowing steam flow rate took account of the result of unaccounted-for leakage tests and the water level change of condenser hot well, deaerator and boiler drum.
What problem does this paper attempt to address?