Study on Thermal Calculation Method of Circulating Fluidized Bed Boilers

Shuiqing Li
2002-01-01
Abstract:Circulating fluidized bed boilers have many new advantages compared with bubble fluidized boiler, and combustion and heat transfer are very complex. Dust concentration in flue gas decided by circulating rate is a vital factor, which effects heat transfer, combustion and combustion efficiency, steam temperature of boiler superheaters, turn down capability and design of separators. Based on the thermal calculation of 65t/h oil shale CFBC, we studies the effect of the dust concentration in flue gas decided by the circulating rate for combustion and heat transfer in bed and heat transfer in boiler superheaters.