Criteria for Closed Chamber Measurements of Radon Emanation Rate

L MORAWSKA,CR PHILLIPS
DOI: https://doi.org/10.1201/9781003210566-17
2021-01-01
Abstract:Determination of the radon emanation rate from solid materials has been the objective of many studies. The experimental method most often used for determining the radon emanation rate is the so-called “closed chamber” method, in which the growth of radon concentration in a closed chamber is used as the basis for the calculation. Usually, only certain regions of the concentration growth curve are used for calculation purposes, specifically, the initial region of the curve, or the equilibrium value to which it converges. In spite of the experimental simplicity of this method, the mathematical procedures used to calculate the free emanation rate (defined as the emanation rate to an infinite space of air) raise many questions, the answers to which are often contradictory from one implementation of the method to another. The objective of this chapter is to provide quantitative values of the inherent bias in determining the emanation rate for various experimental conditions in the closed chamber method. Quantitative comparison is made among the mathematical models most often applied. An assessment is provided of the usefulness of each model for its assumed geometry of measurement.
What problem does this paper attempt to address?