Development Of Low Pressure Position Sensitive Multiwire Proportional Chamber

Bg Zhang,Wx Wen,Zy Wei,Jx Zhang,Y Feng,Jl Tan,Gm Jin,Zg Xiao,Hw Wang,Hy Wu,Zy Li,Sf Wang,Rj Hu
DOI: https://doi.org/10.3321/j.issn:0254-3052.2003.11.017
2003-01-01
Abstract:A low pressure two dimensional position sensitive multiwire proportional chamber (LPMWPC) has been developed for measurements of low Z charged particles from the nuclear reaction induced by radioactive ion beam. The detector has a 50mm x 50mm sensitive area and consists of three grids (X-position cathode Y-position). The position is determined through delay line readout mode. The detector has good beam transparency and is also adequate to be used in vacuum. The LPMWPC has been tested at a pressure of 800Pa of n-heptane and a bias Voltage of 720V. The test results indicate that the position resolution of the chamber is Deltax = Deltay = I mm and detection efficiency is larger than 80 % for the low Z particle at intermediate energies. This kind of chamber has be used to determine the direction of the incident particle.
What problem does this paper attempt to address?