Experimental Comparison of Flue Gas CO_2 Separation with Membrane Absorption and Chemical Absorption

张卫风,王秋华,方梦祥,骆仲泱,岑可法
DOI: https://doi.org/10.3321/j.issn:1000-6761.2008.05.020
2008-01-01
Abstract:Separation effect of CO_2 from the simulated coal-fired flue gas with membrane absorption and chemical absorption were compared by using a hollow fiber membrane contactor test rig and a packed tower test rig,respectively.MEA aqueous solution was used as absorption solution.CO_2 removal efficiency and absorption solution CO_2 load were investigated in particular with different absorption solution flowrate,temperature and flue gas flowrate.Results show that under different conditions,CO_2 removal efficiency of membrane absorption is higher than that of chemical absorption,while absorption solution CO_2 loads perform different trends.