Structure effect of industrial loop reactors on non-uniform flow characteristics

Ming TANG,Can ZI,Yao YANG,Zhengliang HUANG,Zuwei LIAO,Jingdai WNAG,Binbo JIANG,Yongrong YANG
DOI: https://doi.org/10.11949/j.issn.0438-1157.20160900
2017-01-01
Abstract:Liquid-solid flow and stable operation of a loop reactor were affected by the reactor’s structural parameters. CFD simulation of the industrial polypropylene loop reactor showed clear non-uniform flow phenomenon with segregation at bend and particulate rope in straight tube. Hence, the non-uniform flow under different straight tube height/diameter ratios and straight tube number was quantitatively analyzed by introducing a non-uniformity parameter. Simulated results indicated that non-uniformity of particulate distribution at 2-leg loop reactor’s outlet did not change after the height/diameter ratio exceeded 43. The flow uniformity of particulate distribution at 4-leg loop reactor’s outlet kept increasing with larger height/diameter ratio. When the height/diameter ratio was fixed at 65 and height of the straight tube was kept at 39 m, flow uniformity of particulate distribution at the outlet was improved with more straight tubes. But, the influence of the height/diameter ratio on the outlet’s non-uniformity was more significant than that of straight tube number. The research results could provide guidance for design and optimization of industrial loop reactors.
What problem does this paper attempt to address?